Model | Titan Neo F 1K | Titan Neo F 2K | Titan Neo F 3K |
---|---|---|---|
CAPACITY (KVA/W) | 1KVA / 900W | 2KVA / 1,800W | 3KVA / 2,700W |
INPUT | |||
NOMINAL VOLTAGE | 208/220/230/240VAC | 208/220/230/240VAC | 208/220/230/240VAC |
VOLTAGE RANGE | 80 - 300VAC | 80 - 300VAC | 80 - 300VAC |
NOMINAL FREQUENCY | 50 or 60Hz | 50 or 60Hz | 50 or 60Hz |
FREQUENCY RANGE | 40 - 70Hz | 40 - 70Hz | 40 - 70Hz |
PHASE | Single Phase with Ground | Single Phase with Ground | Single Phase with Ground |
INPUT POWER FACTOR | ≥0.99 @ Nominal Voltage ( 100% load ) | ≥0.99 @ Nominal Voltage ( 100% load ) | ≥0.99 @ Nominal Voltage ( 100% load ) |
OUTPUT | |||
OUTPUT VOLTAGE | 208/220/230/240VAC | 208/220/230/240VAC | 208/220/230/240VAC |
OUTPUT POWER FACTOR | 0.9 | 0.9 | 0.9 |
VOLTAGE REGULATION | ±1% | ±1% | ±1% |
NOMINAL OUTPUT FREQUENCY | 50 or 60Hz | 50 or 60Hz | 50 or 60Hz |
FREQUENCY RANGE (Batt. Mode) | 50Hz or 60Hz ±0.5% | 50Hz or 60Hz ±0.5% | 50Hz or 60Hz ±0.5% |
CURRENT CREST RATIO | 3:01 | 3:01 | 3:01 |
TOTAL HARMONIC DISTORTION (THDv) | ≤3% @ Linear Load ; ≤5% @ Non-Linear Load | ≤3% @ Linear Load ; ≤5% @ Non-Linear Load | ≤3% @ Linear Load ; ≤5% @ Non-Linear Load |
WAVEFORM | Pure Sinewave | Pure Sinewave | Pure Sinewave |
TRANSFER TIME (Typical) | Zero | Zero | Zero |
TRANSFER TIME (Inverter to Bypass) | 4ms ( Typical ) | 4ms ( Typical ) | 4ms ( Typical ) |
OUTPUT SOCKET | 2 x British Socket | 2 x British Socket | 3 x British Socket + 1 x Terminal Block |
PROTECTION | |||
SURGE PROTECTION | IEC 61000-4-5 Level 4 | IEC 61000-4-5 Level 4 | IEC 61000-4-5 Level 4 |
SHORT CIRCUIT PROTECTION | UPS Output Cut Off Immediately or Input Fuse / Circuit Breaker Protection | UPS Output Cut Off Immediately or Input Fuse / Circuit Breaker Protection | UPS Output Cut Off Immediately or Input Fuse / Circuit Breaker Protection |
OVERLOAD PROTECTION | LINE MODE : 105% - 110% Overload warning only ( No shutdown ); | LINE MODE : 105% - 110% Overload warning only ( No shutdown ); | LINE MODE : 105% - 110% Overload warning only ( No shutdown ); |
110% - 125% Warning, transfer to bypass after 60s; | 110% - 125% Warning, transfer to bypass after 60s; | 110% - 125% Warning, transfer to bypass after 60s; | |
125%, Transfer to bypass immediately | 125%, Transfer to bypass immediately | 125%, Transfer to bypass immediately | |
BATTERY MODE : 105% - 110%, Overload warning only ( No shutdown ); | BATTERY MODE : 105% - 110%, Overload warning only ( No shutdown ); | BATTERY MODE : 105% - 110%, Overload warning only ( No shutdown ); | |
110% - 120% Warning, shutdown after 10s; | 110% - 120% Warning, shutdown after 10s; | 110% - 120% Warning, shutdown after 10s; | |
120% Shutdown immediately | 120% Shutdown immediately | 120% Shutdown immediately | |
BYPASS MODE : 110% - 130%, warning only; >130%, shutdown immediately | BYPASS MODE : 110% - 130%, warning only; >130%, shutdown immediately | BYPASS MODE : 110% - 130%, warning only; >130%, shutdown immediately | |
BATTERY | |||
SEALED LEAD ACID MAINTENANCE FREE BATTERY | 12V 7.2AH x 2pcs | 12V 7.2AH x 4pcs | 12V 7.2AH x 6pcs |
BACKUP TIME (Depending on Load) | 20 - 30 minutes | 20 - 30 minutes | 20 - 30 minutes |
RECHARGE TIME | 4 Hour to 90% | 4 Hour to 90% | 4 Hour to 90% |
CHARGER CURRENT (MAX.) | 1A | 1.5A | 1.5A |
EFFICIENCY | |||
EFFICIENCY (Inverter Mode) | 89% | 90% | 91% |
EFFICIENCY (Batt. Mode) | 85% | 88% | 88% |
ECO MODE | 97% | 98% | 98% |
STATUS INDICATOR | |||
LCD DISPLAY | Input / Output Voltage, Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, UPS Fault | Input / Output Voltage, Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, UPS Fault | Input / Output Voltage, Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, UPS Fault |
AUDIBLE ALARMS | Battery Mode, Low Battery, UPS Fault, Overload, Replace Battery, Bypass Mode, Charger Failure / Over Charged, Fan Failure, EPO active | Battery Mode, Low Battery, UPS Fault, Overload, Replace Battery, Bypass Mode, Charger Failure / Over Charged, Fan Failure, EPO active | Battery Mode, Low Battery, UPS Fault, Overload, Replace Battery, Bypass Mode, Charger Failure / Over Charged, Fan Failure, EPO active |
COMMUNICATION | |||
POWER MANAGEMENT SOFTWARE | Support Windows Family, Linux & MAC | Support Windows Family, Linux & MAC | Support Windows Family, Linux & MAC |
- UPS Status Monitoring | - UPS Status Monitoring | - UPS Status Monitoring | |
- Schedules Shutdown / Restart | - Schedules Shutdown / Restart | - Schedules Shutdown / Restart | |
- Runtime Configuration | - Runtime Configuration | - Runtime Configuration | |
- Email & SMS Notification | - Email & SMS Notification | - Email & SMS Notification | |
- User Programmable Command File | - User Programmable Command File | - User Programmable Command File | |
- Safety Shutdown | - Safety Shutdown | - Safety Shutdown | |
INTERFACE | USB Port & RS 232 Port | USB Port & RS 232 Port | USB Port & RS 232 Port |
SNMP SLOT | Yes | Yes | Yes |
EMEGENCY POWER OFF (EPO) | Yes | Yes | Yes |
PHYSICAL | |||
OPERATING ENVIRONMENT | 0-40℃, 20-90% Relative Humidity (Non-Condensing) | 0-40℃, 20-90% Relative Humidity (Non-Condensing) | 0-40℃, 20-90% Relative Humidity (Non-Condensing) |
NOISE LEVEL | <45dB | <45dB | <45dB |
DIMENSION (D x W x H)mm | 327 x 140 x 191 | 394 x 151 x 225 | 416 x 196 x 342 |
WEIGHT (KG) | 14.5 | 17.14 | 21.3 |
WARRANTY | |||
UPS WARRANTY | 3 Years Full Warranty Include Parts & Labour . 2 Years Warranty for Battery | 3 Years Full Warranty Include Parts & Labour . 2 Years Warranty for Battery | 3 Years Full Warranty Include Parts & Labour . 2 Years Warranty for Battery |
Model | Titan Neo F 6K | Titan Neo F 10K |
---|---|---|
CAPACITY (KVA/W) | 6KVA / 5,400W | 10KVA / 9,000W |
INPUT | ||
NOMINAL VOLTAGE | 208/220/230/240VAC | 208/220/230/240VAC |
VOLTAGE RANGE | 80 - 300VAC | 80 - 300VAC |
NOMINAL FREQUENCY | 50 or 60Hz (Auto-Sensing) | 50 or 60Hz |
FREQUENCY RANGE | ( 45 ~ 55 ) / (54 ~ 66 )Hz | ( 45 ~ 55 ) / (54 ~ 66 )Hz |
PHASE | Single Phase with Ground | Single Phase with Ground |
INPUT POWER FACTOR | ≥0.99 @ Nominal Voltage ( 100% load ) | ≥0.99 @ Nominal Voltage ( 100% load ) |
OUTPUT | ||
OUTPUT VOLTAGE | 208/220/230/240VAC | 208/220/230/240VAC |
OUTPUT POWER FACTOR | 0.9 | 0.9 |
VOLTAGE REGULATION | ±1% | ±1% |
NOMINAL OUTPUT FREQUENCY | 50Hz or 60Hz ±0.5Hz | 50 or 60Hz ±0.5Hz |
FREQUENCY RANGE (Batt. Mode) | ±0.5% | ±0.5% |
CURRENT CREST RATIO | 3:01 | 3:01 |
TOTAL HARMONIC DISTORTION (THDv) | ≤2% @ Linear Load ; ≤5% @ Non-Linear Load | ≤2% @ Linear Load ; ≤5% @ Non-Linear Load |
WAVEFORM | Pure Sinewave | Pure Sinewave |
TRANSFER TIME (AC TO DC) | Zero | Zero |
OUTPUT SOCKET | Terminal Block | Terminal Block |
PROTECTION | ||
SURGE PROTECTION | IEC 61000-4-5 Level 4 | IEC 61000-4-5 Level 4 |
SHORT CIRCUIT PROTECTION | UPS Output Cut Off Immediately or Input Fuse / Circuit Breaker Protection | UPS Output Cut Off Immediately or Input Fuse / Circuit Breaker Protection |
OVERLOAD PROTECTION | LINE MODE : 105% - 125% transfer to bypass after 1min; 125% - 135% transfer to bypass after 30s; |
LINE MODE : 105% - 125% transfer to bypass after 1min; 125% - 135% transfer to bypass after 30s; |
>135% transfer to bypass after 10s; | >135% transfer to bypass after 10s; | |
>150% transfer to bypass after 1s | >150% transfer to bypass after 1s | |
BATTERY MODE : 105% - 125% shutdown after 1min; | BATTERY MODE : 105% - 125% shutdown after 1min; | |
125% - 135% shutdown after 30s, | 125% - 135% shutdown after 30s, | |
>135% shutdown after 1s | >135% shutdown after 1s | |
BYPASS MODE : 120% - 150% cut off output & alarm contimually after 1min; >150% shutdown immediately | BYPASS MODE : 120% - 150% cut off output & alarm contimually after 1min; >150% shutdown immediately | |
BATTERY | ||
SEALED LEAD ACID MAINTENANCE FREE BATTERY | 12V 7AH x 16pcs | 12V 9AH x 16pcs |
BACKUP TIME (Depending on Load) | 20 - 30 minutes | 20 - 30 minutes |
RECHARGE TIME | 7 Hour to 90% | 9 Hour to 90% |
CHARGER CURRENT (MAX.) | 1A | 1A |
EFFICIENCY | ||
EFFICIENCY (Inverter Mode) | 92% | 92% |
EFFICIENCY (Batt. Mode) | 90% | 90% |
ECO MODE | 96% | 96% |
STATUS INDICATOR | ||
LCD DISPLAY | Input / Output Voltage, Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, UPS Fault | Input / Output Voltage, Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, UPS Fault |
AUDIBLE ALARMS | Battery Mode, Low Battery, UPS Fault, Overload, Replace Battery, Bypass Mode, Charger Failure / Over Charged, Fan Failure, EPO active | Battery Mode, Low Battery, UPS Fault, Overload, Replace Battery, Bypass Mode, Charger Failure / Over Charged, Fan Failure, EPO active |
COMMUNICATION | ||
POWER MANAGEMENT SOFTWARE | Support Windows Family, Linux & MAC | Support Windows Family, Linux & MAC |
- UPS Status Monitoring | - UPS Status Monitoring | |
- Schedules Shutdown / Restart | - Schedules Shutdown / Restart | |
- Runtime Configuration | - Runtime Configuration | |
- Email & SMS Notification | - Email & SMS Notification | |
- User Programmable Command File | - User Programmable Command File | |
- Safety Shutdown | - Safety Shutdown | |
INTERFACE | USB Port & RS 232 Port | USB Port & RS 232 Port |
SNMP SLOT | Yes | Yes |
EMEGENCY POWER OFF (EPO) | Yes | Yes |
SURGE PROTECTION & FILTERING | ||
SPIKE, SURGE & LIGHTNING PROTECTION | Yes | Yes |
OVERLOAD, SHORT CIRCUIT PROTECTION | Yes | Yes |
PHYSICAL | ||
OPERATING ENVIRONMENT | 0-40℃, 0-90% Relative Humidity (Non-Condensing) | 0-40℃, 0-90% Relative Humidity (Non-Condensing) |
NOISE LEVEL | <60dB @ 1 Meter | <55dB @ 1 Meter |
DIMENSION (D x W x H)mm | 412 x 196 x 702 | 412 x 196 x 702 |
WEIGHT (KG) | 63 | 68 |
WARRANTY | ||
UPS WARRANTY | 3 Years Full Warranty Include Parts & Labour . 2 Years Warranty for Battery | 3 Years Full Warranty Include Parts & Labour . 2 Years Warranty for Battery |